DiaSorin
LIAISON NES
Product overview
CLIA-waived molecular point-of-care · Updated Nov 22, 2026

LIAISON NES®

Molecular point-of-care respiratory testing, CLIA-waived. Flu A/B, RSV and COVID-19 from a single nasal swab — plus Group A Strep — with confident answers in about 15 minutes.

CLIA-waived ~15 min to result <1 min hands-on 3 steps Single swab · 3 targets No confirmatory testing
↓  Download the DiaSorin brochure (PDF)
LIAISON NES instrument with Flu A/B, RSV & COVID-19 test cartridges
FDA cleared 510(k) K251978 Flu A/B, RSV & COVID-19 · Dec 23, 2025
CLIA complexity Waived — CW250008 / CW260004 Both assays, by application
Why it matters now

Respiratory season is the close.

COVID activity is picking up in South Texas and the respiratory panel is the everyday workhorse in front-office medicine. DiaSorin positions the NES for same-visit test-and-treat decisions across exactly the call points on your route.

A clinician loading a test cartridge into the LIAISON NES instrument at the point of care
Close-up of a gloved hand sliding a test cartridge into the LIAISON NES
The LIAISON NES® at the point of care. Load the cartridge, close the door, walk away — a molecular result in about 15 minutes, run by non-laboratory staff in a CLIA-waived setting.
🩺

Pediatrics

Fast Flu/RSV answers parents can act on before they leave the room. No age restrictions on the assays.

🌿

Geriatrics

Confirmatory molecular results reduce send-out lag in higher-risk patients during peak season.

🏥

Family practice

One swab, three respiratory targets, plus Group A Strep on a separate throat swab — the full season menu.

⚡

Urgent care & ER

About 15 minutes keeps the visit moving. Point-of-care testing is associated with shorter emergency-department stays.

📌
Season framing from the vendor: Arnold Barrera (DiaSorin) raised the South Texas COVID uptick in his September 2, 2026 note to the South Central team and invites virtual or face-to-face customer meetings. His number is in Contacts.
Key specs

Everything a clinic manager asks in the first five minutes.

Drawn from the DiaSorin brochure (BR1129102.US.0226) and the official Instructions for Use. Where the brochure and the IFU differ, the IFU governs — flagged below.

ManufacturerDiaSorin Molecular LLC
SystemLIAISON NES® (instrument NES1001)
AssaysFlu A/B, RSV & COVID-19 (NES4450) · Group A Strep (NES2850)
Sample typeAnterior nasal swab (respiratory) · professionally collected throat swab (strep)
Runtime~15 min (brochure). Group A Strep IFU: about 18 min; positives may call out early at ~13 min (brochure)
Hands-on timeUnder 1 minute
RegulatoryCLIA-waived. Respiratory: K251978 / CW250008 (Dec 23, 2025). Strep: K260333 / CW260004 (Jun 15, 2026)
StorageRoom-temperature reagents. Per IFU: do not refrigerate or freeze cartridges, swabs, or sample vials
ConnectivityLIS/EMR integration capabilities · centralized device management · remote firmware updates
Ordering

Part numbers, both sides of the house.

DiaSorin part numbers and orderable numbers from the brochure ordering table. Tap any part number to copy.

Ordering table

Brochure ordering table
McKesson #DiaSorin partItemKit sizeCPT
1289500 NES4450 LIAISON NES® Flu A/B, RSV & COVID-19 Assay10 tests87637
1289505 NES4460 Flu A/B, RSV & COVID-19 Control Kit20 (10 pos / 10 neg)—
1290030 NES1001 LIAISON NES® Instrument1 instrument—
1289508 NES4001 COPAN FLOQSwabs®100 swabs—
confirm with your account team NES2850 LIAISON NES® Group A Strep Assay10 tests87651
confirm with your account team NES2860 Group A Strep Control Kit20 (10 pos / 10 neg)—
CPT 87637 = multiplex amplified probe for SARS-CoV-2, influenza A & B, and RSV. CPT 87651 = group A strep, amplified probe. CLIA-waived (QW) rows carry the same Medicare rate. Group A Strep does not count toward the 6×6 program's 6-kit initial buy.
Workflow

Three steps, under a minute of hands-on time.

The brochure's promise, mapped to the IFU test procedure. Designed for non-laboratory staff in a CLIA-waived setting — the clinical studies were run by untrained operators.

01
Collect

Collect the specimen

Anterior nasal swab for Flu A/B, RSV & COVID-19 — professionally collected or self-collected under supervision. Professionally collected throat swab for Group A Strep. Place into the NES sample vial.

02
Load

Load the cartridge

Transfer the full vial contents into the cartridge sample port and close the cap securely. Per IFU: run immediately and keep the cartridge upright.

03
Run

Insert and run

Log into the instrument, insert the cartridge, close the door. About 15 minutes to a result. Group A Strep positives may call out and terminate early at about 13 minutes.

< 1 minHands-on time
3Steps to run
~15 minTurnaround*
NoneConfirmatory testing
Room tempReagent storage

*Brochure figure. The Group A Strep IFU (Rev. 02) states results in about 18 minutes; use the IFU as the assay instruction.

📦

Effortless implementation

Complete training kit with controls included. Sample collection kit included.

🔄

On-demand readiness

Room-temperature reagents for easy storage and access. Firmware updates deployed remotely.

🔗

Seamless connectivity

Centralized management of devices. LIS/EMR integration capabilities.

Clinical performance

Numbers straight from the Instructions for Use.

Not brochure rounding — these are the prospective-study tables in the official IFUs, with confidence intervals. Respiratory agreement is versus an FDA-cleared molecular assay; Group A Strep is versus culture.

Prospective data set — Table 4, IFU DSM-IFUK-US-NES4450 Rev. 02

Verified in IFU
TargetPositive percent agreement95% CINegative percent agreement95% CI
Influenza A96.5% (384/398)94.2–97.9%97.2% (1140/1173)96.1–98.0%
Influenza B97.1% (34/35)85.5–99.5%99.7% (1531/1536)99.2–99.9%
RSV90.3% (102/113)83.4–94.5%99.8% (1455/1458)99.4–99.9%
COVID-1998.4% (63/64)91.7–99.7%99.4% (1498/1507)98.9–99.7%
Study design: specimens prospectively collected October 2024 – March 2025 at seven geographically diverse U.S. sites; pediatric and adult patients with respiratory symptoms; all testing at CLIA-waived facilities by untrained operators. 1,692 specimens enrolled; after a single test, 1,571 generated valid results — 98.7% first-test success (1571/1591). Comparator: FDA-cleared molecular assay. Some discordant results were positive or negative by standard of care / alternate molecular testing (IFU footnotes a–h).

Group A Strep — IFU IFUK-US-NES2850 Rev. 02

Verified in IFU
MeasureResult95% CI
Sensitivity (vs culture)100% (104/104)96.44–100%
Specificity (vs culture)95.85% (1223/1276)94.61–96.81%
Study design: 1,423 throat swab specimens prospectively collected April 2025 – December 2025 at four geographically diverse U.S. sites; 1,380 analyzed; S. pyogenes prevalence 7.54% (104/1380); testing by untrained operators. Brochure rounds specificity to 95.9%.

Outcomes that matter to a clinic

From the DiaSorin brochure (BR1129102.US.0226), each with its published reference below.

25%
reduction in emergency department length of stay1
Baron et al., Microbiol Spectr, 2022
70%
avoided unnecessary antibiotics after an RSV-positive test2
Pharmacy Times, Nov 2025
60%
decrease in time to treatment for flu infections3
Martinot et al., Open Forum Infect Dis, 2019
44%
fewer antibiotic prescriptions in group A strep-negative patients4
Dubois et al., Clin Microbiol Infect, 2021
93%
of patients believe point-of-care testing can improve their care5
Lilly et al., Point Care, 2020
🗣️
Keep it factual: these are published associations from point-of-care testing literature — they support the test-and-treat conversation and antibiotic stewardship. They are not a guarantee of any specific clinic's results.
Reimbursement

Listed by code, pulled from the payers' own files.

Medicare from the Centers for Medicare & Medicaid Services clinical laboratory fee schedule public-use file; Texas Medicaid from the Texas Medicaid & Healthcare Partnership clinical laboratory fee schedule. Retrieved November 22, 2026.

Medicare — CLFS

CMS 26CLABQ4
CPTAssayNational rate
87637Flu A/B, RSV & COVID-19 (multiplex amplified probe)$142.63
87651Group A Strep (DNA amplified probe)$35.09
CY 2026 Q4 release (PUF_CLFS_CY2026_Q4V1, 2,243 records), rates effective January 1, 2026. CLIA-waived (QW) rows price identically.

Texas Medicaid — TMHP

Fee schedule PRCR494C
CPTClinical lab feeAdjusted fee
87637$142.63$119.81
87651$35.09$29.48
Texas Medicaid clinical laboratory fee schedule (PRCR494C), file dated September 14, 2026; last pricing review March 1, 2026. Note codes 2 and 9: code 2 = clinical lab fee schedule procedure; code 9 = nurse practitioner / clinical nurse specialist / physician assistant / certified nurse-midwife fee reflects 100% of the physician fee. Sole Community Hospital lab columns run higher ($232.62 / $195.40 for 87637).
⚖️
Coverage varies: most payors reimburse these codes, but always verify with your own contracts before making decisions. Reimbursement is not a guarantee of payment — this is a reference list, not a revenue projection.
Programs & terms

Two ways to place an instrument, one deadline in play.

6×6 Acceleration Placement Program

⏱
Runs through December 31, 2026. — New customers only. Program details subject to approved paperwork and eligibility review.

A faster path to placing a LIAISON NES with qualified new customers:

1
Buy 6 respiratory (4-plex) assay kits. The initial purchase places one NES instrument. Group A Strep does not count toward the 6-kit buy.
2
Use the NES for 6 months. No initial volume commitment. Additional 4-Plex kits may be purchased as needed.
3
Convert whenever the fit is clear. Move to a committed agreement at any point and begin negotiated pricing immediately.

After 6 months, three simple options: keep the instrument (no contract required), move to a contract with negotiated pricing based on volume and structure, or return the instrument if NES is not the right fit.

Other program highlights per the flyer: negotiated pricing can start early on conversion · no upfront volume commitment.

View the 6×6 program flyer (PDF) →

Placement agreement

Placement program
📄
Simple 2-page agreement with reimbursement protection language.
📅
3-year term. Aggregate spend commitment over the term — no annual commitment.
🔧
Overnight instrument replacement if the unit is broken, damaged, or faulty.
🧪
90-day evaluations available, and they can roll into a placement agreement.
🚚
Logistics: McKesson stocks the test kits; DiaSorin drop-ships all instruments.
💰
Capital purchase: a purchase option is available — ask your account team for current pricing.
🧾
The agreement document is issued per deal — the short 2-page placement agreement is generated with approved paperwork (program details are subject to eligibility review). Ask your account team for a copy.
Contacts

Who to call for what.

AB
Vendor — DiaSorin

Arnold Barrera

Molecular Account Executive — NES 737-308-7414 [email protected] cc: [email protected]
MK
McKesson — account

Your account team

Pricing, paperwork, and placements — your McKesson account manager www.mypss.com
DS
DiaSorin — support & product

Technical support

(800) 838-4548 us.diasorin.com/en/liaison-nes IFUs & quick-reference guides on the resources page
Sources

Every number on this page, traced.

Primary documents first, retrieved November 22, 2026. Official product documents.

LIAISON NES® brochure BR1129102.US.0226 — download PDF or us.diasorin.com. Workflow stats, outcome figures, ordering table.
LIAISON NES® 6×6 Acceleration Placement Program flyer — download PDF. Program mechanics, deadline December 31, 2026.
Instructions for Use — Flu A/B, RSV & COVID-19, DSM-IFUK-US-NES4450 Rev. 02 — us.diasorin.com PDF. Clinical agreement table (Table 4), study design, success rate.
Instructions for Use — Group A Strep, IFUK-US-NES2850 Rev. 02 — us.diasorin.com PDF. Sensitivity / specificity, study design, ~18-minute runtime.
Centers for Medicare & Medicaid Services — Clinical Laboratory Fee Schedule, CY 2026 Q4 (release 26CLABQ4, file PUF_CLFS_CY2026_Q4V1) — cms.gov. 87637 = $142.63, 87651 = $35.09, effective January 1, 2026.
Texas Medicaid & Healthcare Partnership — Clinical Laboratory Fee Schedule (PRCR494C), September 14, 2026 — tmhp.com PDF. 87637 adjusted $119.81; 87651 adjusted $29.48.
U.S. Food & Drug Administration — 510(k) K251978 (decision summary, cleared Dec 23, 2025) and K260333 (decision summary, cleared Jun 15, 2026); CLIA waiver by application determinations CW250008 (PDF) and CW260004 (PDF).
Outcome references (via brochure): 1. Baron A, Peyrony O, Salmona M, et al. Microbiol Spectr. 2022;10(4):e0063622. 2. Ferruggia K. Pharmacy Times, Nov 4, 2025. 3. Martinot M, Greigert V, Gravier S, et al. Open Forum Infect Dis. 2019;6(7):ofz312. 4. Dubois C, Smeesters PR, Refes Y, et al. Clin Microbiol Infect. 2021;27(12):1736-1745. 5. Lilly CM, Ensom TE, Teebagy J, et al. Point Care. 2020;19(4):112-115.